Chapter 12 Descriptions of Parameter SettingsC2000 Plus 
 
12.1-02-19
Settings  Functions  Descriptions 
36 
Error output selection 2 
(Pr.06-24) 
Activate when Pr.06-24 is ON. 
37 
Error output selection 3 
(Pr.06-25) 
Activate when Pr.06-25 is ON. 
38 
Error output selection 4 
(Pr.06-26) 
Activate when Pr.06-26 is ON. 
39 
Position reached   
(Pr.11-65, Pr.11-66) 
Activate when the position control point reaches Pr.11-65, Pr.11-
66. 
40 
Speed reached 
(including speed) 
Activate when the output frequency reaches the setting frequency 
or stopped. 
42 Crane function 
Use this function with Pr.02-32, Pr.02-33, Pr.02-34, Pr.02-57 and 
Pr.02-58. 
Refer to the crane function examples below. 
43 
Actual motor speed 
detection 
Activate when motor actual speed is less than Pr.02-47. 
44  Low current output  This function needs to be used with Pr.06-71–Pr.06-73 
45 
UVW output 
electromagnetic valve 
switch 
Use this function with external terminal input = 49 (drive enabled) 
and external terminal output = 45 (electromagnetic valve 
enabled), and then the electromagnetic valve is ON or OFF 
according to the status of the drive.       
 
  
46  Master dEb output   
When dEb rises at the master, MO sends a dEb signal to the 
slave. Output the message when the master triggers dEb. This 
ensures that the slave also triggers dEb. Then slave follows the 
deceleration time of the master to stop simultaneously with the 
master.