19
AVR-4810CI/AVR-4810
1.3. Error display
See the following table for each "Error information" display and its contents (status).
Display order is ①②③④⑤⑥⑦ .
Condition State Display
① Sub-µcom
NG
No response from Sub-µcom
"□SUB□ □ERROR□01□□"
② DIR NG
No response from DIR
"□DIR□ □ERROR□01□□"
③ DSP1 NG
When DSP boot, executing DSP reset makes no change to DSP1 FLAG0
port "H".
"□ DSP1□ERROR □01□ □"
No change to DSP1 FLAG0 port "H" before issuing DSP command.
"□ DSP1□ERROR □02□ □"
When DSP data read, executing WRITE="L" makes no change to ACK="H".
"□ DSP1□ERROR □03□ □"
When DSP data read, executing REQ="L" makes no change to ACK="L".
"□ DSP1□ERROR □04□ □"
When DSP data write, executing WRITE="H" makes no change to ACK="H".
"□ DSP1□ERROR □05□ □"
When DSP data write, executing REQ="L" makes no change to ACK="L".
"□ DSP1□ERROR □06□ □"
When DSP special code boot, executing DSP reset makes no change to
DSP1 FLAG0 port "H".
"□ DSP1□ERROR □11□ □"
No change to DSP1 FLAG0 port "H" before issuing DSP special read com-
mand.
"□ DSP1□ERROR □12□ □"
No change to DSP1 FLAG0 port "H" before DSP version read.
"□ DSP1□ERROR □13□ □"
④ DSP2 NG
When DSP boot, executing DSP reset makes no change to DSP2 FLAG0
port "H".
"□ DSP2□ERROR □01□ □"
No change to DSP2 FLAG0 port "H" before issuing DSP command.
"□ DSP2□ERROR □02□□ "
When DSP data read, executing WRITE="L" makes no change to ACK="H".
"□ DSP2□ERROR □03□ □"
When DSP data read, executing REQ="L" makes no change to ACK="L".
"□ DSP2□ERROR □04□ □"
When DSP data write, executing WRITE="H" makes no change to ACK="H".
"□ DSP2□ERROR □05□ □"
When DSP data write, executing REQ="L" makes no change to ACK="L".
"□ DSP2□ERROR □06□ □"
When DSP special code boot, executing DSP reset makes no change to
DSP2 FLAG0 port "H".
"□ DSP2□ERROR □11□ □"
No change to DSP2 FLAG0 port "H" before issuing DSP special read com-
mand.
"□ DSP2□ERROR □12□ □"
No change to DSP2 FLAG0 port "H" before DSP version read.
"□ DSP2□ERROR □13□ □"
⑤ DSP3 NG
When DSP boot, executing DSP reset makes no change to DSP3 FLAG0
port "H".
"□ DSP3□ERROR □01□ □"
No change to DSP3 FLAG0 port "H" before issuing DSP command.
"□ DSP3□ERROR □02□ □"
When DSP data read, executing WRITE="L" makes no change to ACK="H".
"□ DSP3□ERROR □03□ □"
When DSP data read, executing REQ="L" makes no change to ACK="L".
"□ DSP3□ERROR □04□ □"
When DSP data write, executing WRITE="H" makes no change to ACK="H".
"□ DSP3□ERROR □05□ □"
When DSP data write, executing REQ="L" makes no change to ACK="L".
"□ DSP3□ERROR □06□ □"
When DSP special code boot, executing DSP reset makes no change to
DSP3 FLAG0 port "H".
"□ DSP3□ERROR □11□ □"
No change to DSP3 FLAG0 port "H" before issuing DSP special read com-
mand.
"□ DSP3□ERROR □12□ □"
No change to DSP3 FLAG0 port "H" before DSP version read.
"□ DSP3□ERROR □13□ □"
⑥ EEPROM NG
Error appeared in EEPROM checksum.(*** is a block address number.)
"□E2PROM□ERR***□ □"
⑦
Both SUB/DSP
/EEPROM OK
(No error display, version display