3.1. Items to Be Prepared
(1) Software suite to be written (FLASHSTA.exe, Update le.)
(2) Personal Computer OS is Windows7 (Be installed "
FLASHSTA.EXE
")
(3) RS-232C cable (9P (Male), Straight).
(4) 8U-210100S WRITING KIT (OLD JIG : SPK-581 WRITING KIT)
606050028012P : 7P FFC (Straight)
3.2. Connecting the WRITING KIT to This Unit
(1) Check that the power of this unit is off.
(2) Connect the RS-232C cable to the computer and WRITING KIT.
(3) Connect the update terminal of this unit to the WRITING KIT.
RESET
5V
3.3V
LOW
HIGH
CNVSS EPM CE DSPBOOT
Computer
① Connect the RS-232C cable.
  (Straight cable)
↑Top side is contacts of
flexible card cable.
Using the 7P FFC(Straight).
is 1PIN side.
→This side is contacts of
flexible card cable.
is 1PIN side.
② Align the switch in the direction of the arrow.
④ Power ON of the this unit.
Press "RESET" button.
3.3. Run the FLASHSTA
(1) Double-click "
FLASHSTA.EXE
" to launch M16 Flash Start.
(2) Select [
Internal ash memory
] in the Select Program.
Select the COM Port number.
Click [OK].
(3) Click [Refer...].
3. Updating via System u-com (U0102)