21
u
RFRP
"
1
3
"
X X X X
R F R P
(
1
,
3
ashing/XXXX:Adjustmentvalue
)
(
2) Press the
2
button, "4. CD test mode (1)" display reappears.
※
If auto adjustment is not completed, proper values are not displayed.
4.7 Laser current is display
(1) When the
2
button is pressed for over 1 second while the RCD-M38 is in the stop mode(Display of "4. CD test mode
(1)"), the laser turns on and the laser current is measured.
"
1
3
"
S / C : X X m A / Y Y m A
L A S E R C U R R E N T
(
1
,
3
ashing/XX:Storeddata(storedintheEEPROM)/YY:Currentvalue
)
• Therstcurrentvalueismeasured3secondsafterthelaserturnson.
• Thecurrentvalueisupdatedevery3seconds.
• ThelaserdrivecurrentundergoesA/Dconversionforcalculation.Decimalvaluesarediscarded.
(
2) Press the
2
button, "4. CD test mode (1)" display reappears.
※
Stored data is not cleared, initialazation of "3. Cold start mode".
4.7.1 Overwriting the stored data
(1) When the
1
/
3
button is pressed for over 5 seconds while the laser current is displayed, the current value is stored
in the EEPROM (overwriting the stored data).
"
1
3
"
S T O R E D
L A S E R C U R R E N T
(
1
,
3
ashing
)
(
2) Press the
1
/
3
button, the initial value is stored in the EEPROM
(3) Once rewriting is completed, the display in No.4.7(1) reappears.
※
Rewriting is performed upon shipment from the factory and when the mechanism is replaced.