Please observe the following instructions for installing DENSITY:
1. This appliance is not intended for use by person (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
2. Children should be supervised to ensure that they do not play with this appliance.
3. The unit must be installed without blocking escape routes.
4. Verify the fog does not limit the visibility near: stairs, moving objects that may cause falls,
injuries or any damage to people.
5. When using the product in multi-storey buildings, if the escape route runs through an area which is
protected by a fogging system, it is recommended to install a vocal warning that provides instructions
on the behaviour to follow.
6. Do not look directly into the nozzle. Do not add any other substance into the bags.
7. The nozzle may reach high temperatures, touching it may cause burns.
8. When DENSITY produces fog avoid staying closer than 1 meter from the unit.
9. Before testing DENSITY, remember to report it in advance to the firefighters in your area to avoid false
alarms.
10. Remember to put warning labels about the presence of DENSITY on the windows.
11. Report its installation to the firefighters in your area and to other institutions if needed.
12. It is necessary to add an external switch to separate the fog generator from the alarm system, it
should be activated before the maintenance to avoid that input tests, for example, it can activate
the fog generator.
13. Never direct the fog jet towards an object or a wall less than 2 meters away and if possible increase
the suggested minimum distance. Thanks to the power of the jet, DENSITY reaches and exceeds more
than 10 meters away in the first 3 seconds from the point where the unit is installed.
14. When setting the shooting time interval between the minimum and maximum shown in the shooting
table, avoid “overshooting” even if the produced fog is dry and generally doesn’t leave residue.
A shot that goes far beyond the recommended seconds can create residue problems in the room.
15. Install it at an height of about 2,5 meters to not let it be reached, avoiding possible tampering.
16. Do not move the unit when it is still hot.
17. The main body of DENSITY, which has the heating system enclosed inside a metal frame, should not
be opened unless by specific and authorized service centers. Do not open and touch for any reason
the insulation before 24 hours DENSITY has been shut o. The internal part may reach really high
temperature.
18. Do not activate the DENSITY unit before the installation is completed.
19. Insert the fluid bag as the last procedure and verify the anti-tampering function if present.
20. When the installation is finished, always test the system.
21. Install DENSITY avoiding any obstacles in front of it which can prevent the spreading of the fog.
22. The DENSITY unit should not be exposed to water spray or dripping.
23. Request to DENSITY or its distributors to take part in courses for installers to ensure the optimal
installation of the equipment.
24. The content of the bags is mechanically predetermined and can be subject to variations +/- 10%.
4. Installation tips