4
5. Technical specifications
The red led ON related with the “empty” signal shows that the unit needs to be refilled,
even if fluid for a full shot is still available.
It is recommended to always have available a new refill and to proceed to replace it as soon as
possible.
Weight without bag
Max fog emission in a single shot
*Total fog emission capacity with full bag
Fluid bag capacity (NOT included)
Working time without mains power
Max power on heating system
Average power consumption during heating
Heating time
Average power consumption
Maximum current consumption at 12 V
Battery type (not included)
Tamper lid switch (NOT INCLUDED)
Anti-tear o and anti-shift
3,8 Kg
130 m
3
(visibility < 1 m)
Around 780 m
3
1 x 500 ml
Around 1 hour
300 W
300 W
Around 20 minutes
32 W
1,2 A
Pb 1.2 Ah 12V
Optional
n/a
Density® Basic
* Industrial standard as from other manufacturers
It is always recommended to secure the fog generator to a wall even when it is placed on a flat surface.
The optional mounting kit for Density
®
Basic, mainly recommended for ceiling installation, include both battery and
fluid bag holders. An optional orientable 15° (pan & tilt) VESA module is available for wall mounting, it can also simplify
standard installation by allowing to use back holes for the routing of cables.
Always verify that the bracket or the support surface are suitable for the weight of the unit.
It is suggested not to install the unit behind walls in a limited closed area without a specific ventilation, in order to
prevent a possible overheating. Always verify that for Density
®
Basic ceiling/horizontal installation
the temperature of the rooms doesn’t exceed 40°C. To avoid injuries please securely fix the fogging unit to the wall
according to the installation instructions.
After removing the unit from the package, unscrew the side four screws of the plastic front panel.
Remove the front panel and uncover the electrical circuit (hereinafter referred to as PCB), the DC12V power supply,
the thermal unit and the fluid bag. (Fluid bag is sold separately).
- Do not disconnect the unit immediately after the shot
- Change the battery every two years
- Change the bag as soon as the “empty” signal appears
- The generator cannot be activated on a surface that does not allow air circulation from top and bottom slots
WARNING:
6. Installation