INSTALLATION INSTRUCTIONS AND
HOMEOWNER’S MANUAL
Models:
COND-OCD-09
COND-OCD-12
COND-OCD-18
COND-OCD-24
COND-OCD-30
COND-OCD-36
INSTALLER / SERVICE TECHNICIAN:
Use the information in this manual for the installation / servicing and keep the document near the furnace
for future reference.
Communication wire connected between the indoor and outdoor units must be rated for at least 120VAC,
they are protected by the outdoor unit breaker and must be sized appropriatly.
Do not install any metering device on the indoor coil. The expension valve is located in the outdoor unit.
If a metering device is already installed in the indoor coil, it must be removed.
Both refrigerant lines must be separately insulated in order to avoid condensation and to ensure proper
efficiency.
COND-OCD -09 -12 -18 -24 -30 -36
Liquid line dia (In) 1/4 1/4 1/4 1/4 1/4 1/4
Gas line dia (In) 3/8 1/2 5/8 5/8 5/8 5/8
HOMEOWNER:
Please keep this manual near the furnace for future reference.
CAUTION:
Do not tamper with the unit or its controls. Call a qualified service technician.
Manufactured by:
Dettson Industries Inc.
Sherbrooke, Qc, Canada
www.dettson.com
Printed in Canada on 2020-05-08 X40257 Rev.A
100% recycled paper

Questions and Answers

  • S
    Sherri HillAug 19, 2025
    Why does my Dettson Air Conditioner have high pressure protection?
    • C
      Carrie WardAug 19, 2025
      High pressure protection in your Dettson Air Conditioner, resulting in the unit stopping, can be due to poor heat exchange (blockage), ambient temperature being too high, or an excessive amount of refrigerant.
  • S
    Steven BrownAug 21, 2025
    What causes anti-freeze protection in a Dettson COND-OCD-09 Air Conditioner?
    • K
      Karen HammondAug 21, 2025
      Anti-freeze protection in your Dettson Air Conditioner, which causes the outdoor unit to stop in cooling mode, can be triggered by poor air exchange in the indoor unit, abnormal fan speed, or a dirty evaporator.
  • C
    Carly RuizAug 23, 2025
    Why does my Dettson Air Conditioner have high temp. protection?
    • J
      Judith DoyleAug 23, 2025
      High temperature protection in your Dettson Air Conditioner, resulting in the unit stopping, can be attributed to poor heat exchange or high ambient temperature.
  • K
    Kendra ThorntonAug 26, 2025
    Why does my Dettson COND-OCD-09 Air Conditioner have frequency limit (overload)?
    • D
      derrickhumphreyAug 26, 2025
      The frequency of your Dettson Air Conditioner may be limited (decreased frequency) due to overload, which can be caused by poor heat exchange or high ambient temperature.
  • T
    theresahubbardAug 27, 2025
    Why does my Dettson COND-OCD-09 Air Conditioner have frequency limit (overcurrent)?
    • B
      blevinsdeniseAug 28, 2025
      The frequency of your Dettson Air Conditioner may be limited (decreased frequency) due to overcurrent, which can be caused by low input voltage, overload, or high system pressure.
  • E
    Edward GatesAug 29, 2025
    Why does my Dettson Air Conditioner have frequency limit (discharge)?
    • T
      Timothy GallagherAug 30, 2025
      The frequency of your Dettson Air Conditioner may be limited (decreased frequency) due to discharge issues, which can be caused by overload, high temperature, lack of refrigerant, or a defective EXV.
  • R
    ramosjamesAug 31, 2025
    Why does my Dettson Air Conditioner have frequnecy limit (anti-freeze)?
    • C
      charleswaltersSep 1, 2025
      The frequency of your Dettson Air Conditioner may be limited (decreased frequency) due to anti-freeze issues, which can be caused by poor indoor heat exchange or the fan running too slowly.
  • P
    prestonashleySep 2, 2025
    What does EEPROM error mean on Dettson COND-OCD-09?
    • E
      Emily FranklinSep 2, 2025
      An EEPROM error on your Dettson Air Conditioner, which causes the unit to stop, indicates a defective outdoor unit (ODU) control board.
  • A
    Amy MillerSep 4, 2025
    What does IPM protection mean for Dettson COND-OCD-09 Air Conditioner?
    • A
      Amy RuizSep 4, 2025
      If your Dettson Air Conditioner stops due to IPM protection, the error should disappear on its own or after a power cycle. If it persists, it may indicate a defective board.
  • A
    Alan BlackSep 6, 2025
    What does ambient sensor error mean on Dettson COND-OCD-09 Air Conditioner?
    • R
      Renee CantrellSep 6, 2025
      An ambient sensor error on your Dettson Air Conditioner, which causes the unit to stop, indicates that the sensor is either damaged or disconnected.