AT commands: Detailed description
41
|
devolo MicroLink ISDN i
|
EN
S52 Bit-oriented option
The contents of register S52 is stored in the nonvolatile memory with the
commands AT&W or AT*W. The individual bits have the following signifi
-
cance:
S53 Bit-oriented option
The contents of register S53 is stored in the nonvolatile memory with the
commands AT&W or AT*W. The setting is only effective in the transfer
phase. The individual bits have the following significance:
16 1 XON/XOFF characters are sent AT\X1
5..6 0 0 Reserved
7 0 0 Automatic bit rate identification on
128 1 Automatic bit rate identification off
Bit Dec. Description Command
Bit Dec. Description
Comman
d
0..1 0 0 DSR always active, CTS always active AT\D0
1 1 DSR tracks answer signal, CTS always active AT\D1
2 2 DSR always active, CTS tracks DCD AT\D2
3 3 DSR tracks answer signal, CTS tracks DCD AT\D3
2 0 0 DCD always active (ON) AT&C0
4 1 DCD displays existing carrier AT&C1
3..7 0 0 Reserved
Bit Dec. Describtion
0..4 0 0 Reserved
5 0 0 No parity bit transmission at 7E1 & 7O1 via ISDN
32 1 Parity bit transmission at 7E1 & 7O1 via ISDN with e.
g. X.75 according to the data format from register S23
6..7 0 0 Reserved