AT commands: Detailed description
45
|
devolo MicroLink ISDN i
|
EN
All V.120 CompuServe nodes can be reached by using Low Layer Compatibil-
ity (LLC) for V.120.
S152 Call signaling delay
A delay of the signaling of incoming calls can be set in register S152. An
incoming call is not signaled to the computer until a preset period of time has
elapsed and the call is still pending on the network side. This register can be
used to prevent a conflict of multiple terminal devices on the same line with
the same service indicator/bearer capability and EAZ/MSN by giving a differ
-
ent device priority. No signaling delay takes place with the default value 0.
S153 CONNECT/NO CARRIER message
The contents of register S153 can be stored with the commands AT&W or
AT*W. The individual bits have the following significance:
4 0 0 Incoming calls on B channel 1 are answered
16 1 Incoming calls on B channel 1 are ignored
5 0 0 Incoming calls on B channel 2 are answered
32 1 Incoming calls on B channel 2 are ignored
6..7 0 0 Reserved
Bit Dec. Description
Valid values 0 to 50 1/10 seconds
Default value 0
Store in nonvolatile memory AT&W or AT*W
Bit Dec. Description
0 0 0 Caller ID of the remote station is not dis-
played after a CONNECT
1 1 Caller ID is displayed after a CONNECT
1 0 0 Caller ID of the remote station is not dis-
played after RING
2 1 Caller ID is displayed after RING