CODE POSSIBLE CAUSE POSSIBLE SOLUTION
18
Detergent type oil being used in pump Drain oil and rell pump using
SAe 5W-40
full syntheticoil.
19
Motor overload protection switch has tripped
See Motor Overload underFeatures.
20
Extension cord is wrong length or gauge Check for proper gauge wire and cord length. See
Extension Cords underInstallation.
21
Loose electrical connections Contact a
factory service center or a
authorized servicecenter.
22
Possible defective motor or starting capacitor Contact a
factory service center or a
authorized servicecenter.
23
Paint spray on internal motor parts
Contact a
factory service center or a
authorized service center.
Do not operate the
compressor in the paint spray area. See flammable
vapor warning.
24
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker
with higher rating than that specied for your particular
branchcircuit.
2. Check for proper fuse. Use only a time delayfuse.
3. Check for low voltage conditions and/or proper
extensioncord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branchcircuit.
25
Tank pressure exceeds pressure switch cut-in pressure
Motor will start automatically when tank pressure drops
below cut-in pressure of pressureswitch.
26
Pressure release valve on pressure switch has not unloaded
head pressure
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact a
factory service center or a
authorized servicecenter.