56
Adjusting the RMC Stationary PCB
After replacing Stationary Board.
1. Loosen the 4, 3/8” adjustment
nuts.
2. Install the adjustment gauge
(8545-065-001) the gap is 3/16”.
(Make sure the stationary board cover
is in place.)
3. With gap tool installed push until
the stationary board comes in contact
with rotating board. This will set the
spacing at 3/16 of a inch between the
stationary and rotation PCB boards.
4. Tighten the Right side rst then the
left side.
8545-065-001
Tool, MDS Gap
5. Replace the left side cover.
Reconnect the harness to the
stationary board.
Left side upper
and lower tighten
after right side
Right side ad-
justment nut
tighten First.
Sync Auto Dry
If a moisture detection board is replaced or becomes unpaired with the control board, a
sync is required. Simply align both the stationary and rotating boards on the back of the
machine and select Sync Auto Dry. If the sync is successful, the board will display “Auto
Dry Sync Successful”. Please reference the service manual for troubleshooting guides if
the sync is not successful.
Part # 8533-112-001 7/21