8514-311-001 REV PR
The other jumper, located at the upper right side of the component side of the dryer
controller circuit board, is used for choosing either a reversing or non-reversing type of
dryer. This jumper is labeled as REV and NON-REV. This jumper must be in the non-
reversing position, which are the bottom and middle pins. If the jumper is in the
reversing position, the heating part of the dry cycle will not operate properly. The dryer
will not reverse direction either.
The push button, which is located at the lower middle side of the component side of
the dryer controller circuit board, is used to reset all five of the dry cycles to the factory
default settings. It is labeled as DEFAULT SETTINGS. Even the dry cycles that have
been modified using the permanent programming procedure will be changed back to
the factory default settings when using this push button. This push button must be
pressed and held for at least three seconds with power applied to the dryer controller
circuit board.

Table of Contents

Other manuals for Dexter Laundry C-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dexter Laundry C-Series and is the answer not in the manual?

Dexter Laundry C-Series Specifications

General IconGeneral
BrandDexter Laundry
ModelC-Series
CategoryDryer
LanguageEnglish

Related product manuals