EasyManuals Logo

Dexter Laundry WCVD Series Troubleshooting And Fault Codes

Dexter Laundry WCVD Series
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Fault# Description Customer Action
F26 VFD unit has been added or
loose connection.
Soft reset control.
F27 Injection relay PCB has been
added to machine or loose
connection.
Soft reset control.
F28 Optional water valve PCB
has been added or loose
connection
Soft reset control.
Note: Whenever power is turned off to the washer, it must remain off for three minutes for
drive to reset. The washer will not operate correctly if this is done improperly. This will allow
most fault codes to reset that are displayed at washer front. A fault code F-13 or F-21 will
appear on front display if this procedure has not been reset correctly. Note: Should a power
loss occur during cycle and then power returns, P U S H will be displayed and customer must
push a temperature selection button to continue the cycle.
9
Part # 8533-074-001 09/13

Other manuals for Dexter Laundry WCVD Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dexter Laundry WCVD Series and is the answer not in the manual?

Dexter Laundry WCVD Series Specifications

General IconGeneral
BrandDexter Laundry
ModelWCVD Series
CategoryWasher
LanguageEnglish

Related product manuals