Do you have a question about the Deye SUN-50K-G03 and is the answer not in the manual?
Model | SUN-50K-G03 |
---|---|
Rated Power | 50 kW |
Max. DC Input Power | 75 kW |
Max. DC Input Voltage | 1100 V |
Start-up Voltage | 200 V |
MPPT Voltage Range | 200-1000V |
Number of Strings per MPP Tracker | 2 |
Max AC Apparent Power | 55 kVA |
Max. AC Output Current | 80 A |
Rated AC Voltage | 400 V |
AC Voltage Range | 310-480V |
Grid Frequency | 50/60Hz |
Total Harmonic Distortion (THD) | <3% |
Power Factor | 0.8 leading to 0.8 lagging |
DC Injection Current | <0.5% In |
Max. Efficiency | 98.6% |
MPPT Efficiency | 99.9% |
Protection Degree | IP65 |
Output Voltage | 400 V |
Type | Three-phase inverter |
Max. Input Current | 26A |
Operating Temperature Range | -25°C to +60°C |
Cooling Concept | Smart cooling |
Critical safety guidelines for installation and operation.
Criteria for choosing a suitable and safe installation site.
Step-by-step guide for physically mounting the inverter.
Procedures and safety for connecting DC input terminals.
Guidelines for connecting AC output terminals and cable specifications.
Step-by-step procedure for safely starting the inverter.
Step-by-step procedure for safely shutting down the inverter.
List and explanation of error codes and their troubleshooting.