EasyManua.ls Logo

Deye SUN-5K-SG01HP3-EU-AM2 - User Manual

Deye SUN-5K-SG01HP3-EU-AM2
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
R

ł
󾙓󾙒󾙒󾙓󾙕󾙔
󾙚󾙒󾙓󾙕󾙔
󾙘󾙒󾙓󾙕󾙔
󾙗󾙒󾙓󾙕󾙔
󾙓󾙔󾙒󾙓󾙕󾙔
󾙓󾙗󾙒󾙓󾙕󾙔
󾙔󾙒󾙒󾙓󾙕󾙔
󾙔󾙗󾙒󾙓󾙕󾙔

Other manuals for Deye SUN-5K-SG01HP3-EU-AM2

Questions and Answers

  • B
    Brenda LowerySep 12, 2025
    What does Tz_AC_OverCurr_Fault mean on my Deye SUN-5K-SG01HP3-EU-AM2 Inverter?
    • B
      Brian HaydenSep 12, 2025
      If your Deye Inverter displays a Tz_AC_OverCurr_Fault due to an AC side over current fault, check whether the backup load power and common load power are within the specified range. Then, restart the inverter to see if the issue is resolved.
  • J
    Joshua WilliamsAug 25, 2025
    What to do if my Deye Inverter shows AC_Overload_Fault?
    • A
      Alyssa HooverAug 25, 2025
      If your Deye Inverter displays an AC_Overload_Fault, check the backup load connection to ensure it is within the allowed power range.
  • A
    Alex MooreAug 25, 2025
    What does it mean if my Deye Inverter shows DC_Insulation_Fault?
    • J
      Jessica NielsenAug 26, 2025
      If your Deye Inverter shows a DC_Insulation_Fault, it means the PV isolation resistance is too low. You should check if the connection of PV panels and the inverter is firm and correct. Also, verify whether the PE cable of the inverter is connected to ground.
  • A
    alexanderdanielleSep 23, 2025
    What does Tz_EmergStop_Fault mean on my Deye Inverter?
    • S
      stevenmorrisSep 23, 2025
      If your Deye Inverter displays a Tz_EmergStop_Fault, it means the inverter is being remotely controlled.
  • S
    Stephanie RileySep 12, 2025
    What does AC_OverCurr_SW_Failure mean on my Deye SUN-5K-SG01HP3-EU-AM2?
    • D
      David MercadoSep 12, 2025
      If your Deye Inverter displays an AC_OverCurr_SW_Failure due to an AC side over current fault, check whether the backup load power and common load power are within the specified range. Then, restart the inverter to see if the issue is resolved.
  • A
    annettereevesSep 16, 2025
    What does INVERTER_Manual_OFF mean on my Deye Inverter?
    • S
      Sandra SandersSep 16, 2025
      If your Deye Inverter displays INVERTER_Manual_OFF, check whether the switch of the inverter is turned on. You can also try restarting the inverter and restoring the factory settings.
  • J
    Jennifer MillerSep 4, 2025
    What to do if Deye SUN-5K-SG01HP3-EU-AM2 Inverter shows Grid_phase_warn?
    • M
      Matthew BennettSep 5, 2025
      If your Deye Inverter displays a Grid_phase_warn, check the phase sequence connection of the power grid. Try changing the grid type. If there is still no solution check the wiring at the grid end.
  • S
    Sean MarshSep 5, 2025
    What to do if Deye SUN-5K-SG01HP3-EU-AM2 Inverter shows VW_activate?
    • J
      Jo TateSep 5, 2025
      If your Deye Inverter displays VW_activate, measure whether the grid port voltage is too high and check whether the AC cable is too thin to carry current.
  • J
    Jennifer BurnettSep 17, 2025
    What does Parallel_Version_Fault mean on my Deye SUN-5K-SG01HP3-EU-AM2?
    • M
      Monica JohnsonSep 17, 2025
      If your Deye Inverter displays a Parallel_Version_Fault, check whether the inverter versions are consistent. You may need to contact support to upgrade the software version.
  • T
    Tina HudsonAug 30, 2025
    What does it mean if my Deye Inverter shows DC_VoltHigh_Fault?
    • M
      Michael TurnerAug 30, 2025
      If your Deye Inverter displays a DC_VoltHigh_Fault, it means the BUS voltage is too high. Check if the battery voltage is too high and verify that the PV input voltage is within the allowed range.

Deye SUN-5K-SG01HP3-EU-AM2 Specifications

General IconGeneral
ModelSUN-5K-SG01HP3-EU-AM2
TypeHybrid Inverter
Rated Power5000 W
Max. DC Input Power6500 W
Max. DC Input Voltage500V
Max Efficiency97.6%
MPPT Efficiency99.9%
Number of MPPTs2
Max. Input Current per MPPT13A
Nominal AC Output Power5000 W
Max. AC Output Power5500 W
AC Voltage Range180-280V
THDI<3%
Battery Voltage Range40-60V
Max. Charging Current120 A
Max. Discharging Current120 A
Protection DegreeIP65
TopologyTransformerless
Operating Temperature Range-25°C to 60°C
Cooling MethodNatural Convection
Weight25 kg
Nominal AC Voltage230V
Power Factor0.8 leading to 0.8 lagging
AC Grid Frequency Range50/60Hz
CommunicationRS485

Related product manuals