MALFUNCTION TABLE EN
DiBO 25
7 Burner
Check if the burner opening is clear of pollution. Checks pipes and connections
on leaks and external damages. Check the filter and replace if necessary.
Check the sort fuel and the pollution in the tank and clean if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected. The
switching on of the ignition transformer without the ignition pins are connected,
are not permitted. We recommend during maintenance activities certainly
checking the connections of the ignition cables and for the case the burner
would not work, certainly don’t let run the burner.
8
Water tank / fuel tank
Check the water tank / fuel tank on external damages and leaks.
Check when the water tank is filling if the float system works properly.
Malfunction table
At a possible malfunction one can consult the table mentioned below and if you
obtain on this basis no solution, we advise to contact a DiBO- technician and/or
a recognized DiBO- representative.
MALFUNCTION CAUSE SOLUTION
Machine does not start
Electrical supply not connected
Net fuse defective
Main switch on “0”
• Rest malfunctions
Connect the electrical supply
Check net fuse
Put main switch on “1”
Consult an expert
No water pressure
Few water supply
• Filter blocked
Repair water supply
Clean/replace filter cartridge
Instable and to weak pressure
Air in water supply (leaks in water
supply)
Nozzle or lance blocked or worn-
out.
Pressure regulator defect
• Rest malfunctions
Put machine completely without
power! Repair leaks in supply.
Clean or replace
Consult an expert
Consult an expert
No additions of products
Suction line error
Suction filter blocked
Product tank empty
Repair suction line
Clean suction filter
Refill or replace product tank
No hot water
Temperature regulating knob
placed on hot hot water position?
No fuel present in the tank, no
supply of fuel to the burner
Temperature sensor defective
Rest of malfunctions
Put temperature regulating knob
clockwise
Fill the tank, clean/replace the fuel
filter
Consult an expert
Consult an expert
Aerator does not turn
Net fuse defect
Temperature regulating knob
placed on hot hot water position?
Electrical motor defective
Check net fuse
Put temperature regulating knob
clockwise
Consult an expert
HP pump pulse
Leak or congestion in supply
conduit
To much air present
• Clean/replace/repair
Venting (purging) of the cleaner
Hot water temperature is not reached
Temperature too low or working
pressure to high
Higher temperature control +
reducing working pressure