Command descriptions set nfs
ConnectPor LTS Command Reference
77
If alert_type=email,” this option specifies the text to be included in the subject field of an alarm-
triggered email. If alert_type=snmptrap, this option specifies the text to be included in the NFS
Alarm Subject” field of an alarm- triggered SNMP trap.
alert_to=email address
The text to be included in the to” field of an alarm-triggered email.
alert_cc=email address
The text to be included in the cc” field of an alarm-triggered email.
Examples
Enable NFS service
#>set nfs state=on server=192.168.100.100 path=/nfsroot timeout=5 interval=10
Display current NFS settings
#>set nfs
See also
n set smtp
n set snmp