THREE CHANNEL SCALE
ARE SETTING UP A THREE
USING AN SX-D AS SCALE 1
2 AND A
REMOTE PLATFORM WITH NO
CABLE THIS IS THE WAY THE SPECS
&
SHOULD BE SET.
Set
1:
00: Internal Scale 1
Scale 2
10: External Scale
11: Force Balance
SCALE 2:
00: Internal Scale 1
01:
2
10: External Scale
: Force
Normaltv
SCALE 3:
00:
Scale 1
Internal Scale 2
10: External Scale
11: Force Balance
SCALE 4:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
The SX-D Dual Platform Would Be Plugged Into The
Load Cell
The Other Load Cell
Would Be Plugged Into The Remote Platform Connector. (See pg. 12 for remote platform connector)
Using The SX-D Platform In Scale
SX-1 Connector No Power Supply Will Be Necessary As Power Will
Be Supplied By The
In This Case Other Specs That Will Need To Be Set Are As Follows:
Measures Specification: To enter this mode, enter the numeric keys
while
pressing the
Key. The Span Switch must be
to enter this mode.
Spec No.
3 2
Bit 1 Bit 0
20 Minimum
Scale 1)
Minimum Display (Scale 2)
00:2
11:10
21
Weig
001
Point Position
1)
010 :
100 : 0.0000
4*1
22 Weight Decimal Point Position (Scale 2)
000 : 00000 010 : 000.00 100 :
23
Normaltv
Set
0 0 1 1
Display Resolution
11
Used
Zero Setting
00
10:+-10%FS
01
11
00 1 0
Scale Starting Method
0 : Automatic
1 :
Mode
protected by
Span Switch
0 : No 1 : Yes
Scale Type
1 : Double
Scale
Gross Mode
0
: Yes
1
: No
32
1
1
Calibration Mode protected
by Span Switch
0 : Yes
1
: No
Battery Low
Lamp
1: No
Auto Exit from
Add Mode
0 : No 1 : Yes
External Load Cell (Scale 3)
1 : Yes
33
0
Over Weight Mask at
1 : +9d
Weight Decimal Point Position
3}
000 : 00000 010 : 000.00 100
001 : 0000.0 011 : 00.000
36
0 0
Minimum Display
Scale
00 : 2 10 : 5
01:1
Board
Scale 3)
00 : Normal
01 : Prevent
Small vibration
fast change in display
10 : Prevent from Medium vibration
11 : Prevent from
slow
In display
To Select The Minimum Display And Decimal Location Divide Capacity By The Display
Resolution Selected In
In This Case Scale
& 3 Will Be Turned On.
61