14
2.6 Internal Count Display
OPERATION
Key-in
WEIGHT
ZERO NET STABLE
Weighing mode.
0.0 0 0
kg
Press [REZERO]
[REZERO] 8 8 8 8 8 8
Press [Í][Í][T] by holding [REZERO]
To display A / D row data
[REZERO]+
[Í][Í][T]
1,2,0,2,3,4
Press[Ï] key. To display internal Count,
1.0.0.0.0.0
Press[Ï] key. To display A / D row data.
1,2,0,2,3,4
Press[ T ]key returns to weight mode. [ T ] 0.0 0 0
kg
2.7 SPEC Data Setting for Weigh & Measure
Turn on the SPAN SW. (JP1 on Main Board.)
OPERATION Key-in WEIGHT ZERO NET STABLE
Weighing mode.
0.0 0 0
kg
Press [REZERO]
[REZERO] 8 8 8 8 8 8
Press [
Í
] 3 times by holding [REZERO]
SP No. and SP data alternately display
[REZERO]+
[
Í
][
Í
][
Í
]
SP00/ 1 1 0 0
Press [
Í
] to shift a digit to where SPEC data
to be set.
Digit to set the SPEC will blink.
[
Í
] 1 1 0 0
Press [
Ï
] to select SPEC set.
Each time [
Ï
] is pressed, the figure will shift
between 1 and 0.
[
Ï
] 1 1 1 0
Press [REZERO] to save SPEC change. [REZERO] SP01/ 0 0 0 0
Press [TARE] to store the SPEC
setting and
exit to weight mode
0.0 0 0
kg
Note:
1): Press [TARE] key to go back to weighing mode without save
change.