SM5100 INTERFACE
5.3 SCALE IP ADDRESS
This is to set the IP address for PC communication using Ethernet for specific IP address. It
should not be confused with the Scale Ethernet Address as above. The Scale Ethernet
Address is mainly for hardware and Scale IP Address is for software. The software when
communicating to the scale must specify the same IP address on the scale else it will give
error. The default is 192.168.000.000 where the last three digit will change when SPEC 135
change. Please turn on the span switch before proceed.
KEY TO PRESS DISPLAY OPERATION
TARE lb
/lb
Go to Z mode Z1.0 RESET SALES Daily At Z mode
[REZERO] +
[0][4][1][6]
SCALE IP ……. ……. Input or viewing of IP
address
[1][9][2][1][6][8]
[0][0][1][0][1][6]
SCALE IP 192168 001016 Enter IP address e.g.
192.168.001.016
( The last 3 digits cannot
be input as it will change
when SPEC 135 change)
[PLU] Z1.0 RESET SALES Daily Save address and escape
to Z mode
[T] Z1.0 RESET SALES Daily Escape to Z mode without
saving.