EasyManua.ls Logo

Digi WR54 - WR54 Electrical Rating; WR54 Power Connector

Digi WR54
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware setup Connect power
Digi WR54 Hardware Reference
21
For DC installations (with a fixed system ground reference), ground the WR54 chassis to the system
ground reference.
For proper grounding reference:
n Attach the device to a grounded metal surface.
n Connect one end of a short AWG or larger gauge wire to the upper-right grounding hole and
connect the other end to the vehicle chassis.
Special considerations
n Separate Ethernet and power cables from other wiring in the vehicle and route the cables
away from sharp edges.
n Use cable strain relief for installations in high-vibration environments.
WR54 electrical rating
WR54 devices require connection to a conditioned power system that meets these requirements:
n Tolerance within maximum operating voltage range 9 VDC to 36 VDC.
n WR54 power connector on the back of the device requires wiring terminals with the following
specifications:
Wire size: 30-12 AWG
Wire type: copper wire only
Terminal blocks torque: 5-7 pounds per inch
For supply connections, use wires suitable for at least 85° C.
n Power installation must be performed by a qualified electrician, following the National
Electrical Code, ANSI/NFPA 70 and Canadian Electrical Code, Part I, CSA C22.1.
n There must be a disconnect device in front of WR54 devices to protect maintenance workers.
Use a 20 A circuit-breaker as the disconnect device.
n Before doing any maintenance, the maintenance worker must use caution and close the
general power supply.
WR54 power connector
The WR54 has a power connector located on the back of the device:
Pin Connection
1 Ignition sensor
2 Positive
3 Negative
See WR54 electrical rating for information on connecting power to the device.