EasyManuals Logo

Digi XBee User Manual

Digi XBee
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
© 2014 Digi International Inc. 85
XBee/XBee-PRO
®
DigiMesh 2.4 User Manual
Example. In the above example, a device with a 64-bit address of 0x0013A200 40522BAA sends
a broadcast data transmission to a remote device with payload "RxData". Suppose the
transmission was sent with source and destination endpoints of 0xE0, cluster ID=0x2211, and
profile ID=0xC105. If AO=1 on the receiving device, it would send the above frame out its UART.
Node Identification Indicator
Frame Type:0x95 frame (see ND command)
This frame is received when a module transmits a node identification message to identify itself
(when AO=0). The data portion of this frame is similar to a network discovery response frame
(see ND command).
Example. If the commissioning push button is pressed on a remote router device with 64-bit
address 0x0013a200407402ac and default NI string, the following node identification indicator
would be received: 0x7e 0025 9500 13a2 0040 7402 acff fec2 fffe 0013 a200 4074 02ac 2000
fffe 0101 c105 101e 000c 0000 2e33
Checksum 23 0xF5
0xFF - the 8 bit sum of bytes from
offset 3 to this byte.
Frame Fields Offset Example Description

Table of Contents

Other manuals for Digi XBee

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee and is the answer not in the manual?

Digi XBee Specifications

General IconGeneral
Operating Frequency2.4 GHz
RF Data Rate250 kbps
ModelXBee S2C
CategoryControl Unit
Operating Voltage2.1 to 3.6V DC
Operating Temperature-40 to +85 °C
InterfaceUART
Dimensions24.38 x 27.61 x 9.14 mm