9
Light sleep idle time-0ms -3000ms
Light sleep idle time-
0ms - 5000ms
3.2 Command trigger mode
In command trigger mode, the reading module will start shooting and reading when it receives the
trigger signal command sent by the host (that is, the bit 0 of the flag bit 0 x 0002 is written "1"); within
the limited time range of "single reading time" If the reading is successful, the reading module will
output the reading content through the communication interface and stop reading. If you need to
start a new reading, you need to resend the trigger command. If the reading exceeds the single
reading time, the reading will be suspended.
Command trigger mode
Note: In command trigger mode, the serial port command of the trigger signal is: 7E 00 08 01 00 02
01 AB CD; after the module receives the read command, the serial port returns the write success
command: 02 00 00 01 00 33 31, read mode Turn on.
Read the following setting codes to enable and disable the trigger command response:
Trigger command response prohibition
**Trigger command response allowed
1. Single reading time
Please refer to section 3.1.2 for the setting of single reading time length setting code.
3.3 Continuous Mode
Continuous mode is a working mode in which the reading module continuously and cyclically shoots,
reads and outputs information.
In this mode, the default reading interval will be 1000ms after successful reading.
In continuous mode, you can use the trigger level control to pause continuous reading or continue
continuous reading. During continuous reading, you need to maintain the trigger level above 50ms