Type | Handheld bar code reader |
---|---|
Sensor type | CMOS |
Scanner type | 1D/2D |
Read rate (max) | 200 reads/s |
Maximum scan width | 100 mm |
Tilt reading angle | -60 - 60 ° |
Linear (1D) barcodes supported | Codabar, Code 128, Code 32, Code 39, Code 93, EAN 128, EAN-13, EAN-8, GS1 DataBar, GS1-128 (UCC/EAN-128), IATA, ISSN, ITF-14, ITF-6, Industrial 2 of 5, MSI, U.P.C. |
2D (matrix & stacked) barcodes supported | Data Matrix, PDF417, QR Code |
Battery life | 18 h |
Battery type | Built-in battery |
Input voltage | 5 V |
Battery capacity | 2000 mAh |
Power consumption | 120 mA |
Power source type | Battery |
Cable length | 2 m |
Standard interfaces | Bluetooth, RJ-45, USB |
Connectivity technology | Wired |
Storage temperature (T-T) | -40 - 70 °C |
Operating temperature (T-T) | -20 - 50 °C |
Product color | Black |
Housing material | Acrylonitrile butadiene styrene (ABS), Polycarbonate (PC) |
Country of origin | China |
International Protection (IP) code | IP54 |
Operating system installed | Linux |
Compatible operating systems | MAC |
Mobile operating systems supported | Android, iOS |
Windows operating systems supported | Yes |
Harmonized System (HS) code | 84716070 |
Depth | 87 mm |
---|---|
Width | 63 mm |
Height | 165 mm |
Weight | 150 g |
Configures the reading module using setting codes for function modification.
Restores all parameters and functions to their original factory default values.
Sets how barcodes are uploaded, including instant upload and speed settings.
Allows barcodes to be stored internally for later batch upload.
The default mode where the trigger must be pressed for each scan.
Defines how the scanner is triggered, either by edge or level signals.
Sets the maximum duration for a single scanning attempt.
Enables the scanner to enter a low-power state after a period of inactivity.
Configures the idle time before the scanner enters a light sleep state.
Scanner triggers and reads upon receiving a command signal from the host.
The scanner continuously shoots, reads, and outputs information cyclically.
Sets the time between consecutive successful reads in continuous mode.
Prevents reading the same barcode multiple times within a set delay period.
Scanner reads based on changes in ambient light brightness.
Adjusts how sensitive the scanner is to changes in the detection scene.
Time for image stabilization after detecting scene changes in induction mode.
Controls the LED illumination for shooting and reading in various modes.
Manages the aiming device that projects an indicator line for targeting.
Enables or disables all audible prompts from the scanner.
Configures the buzzer type and frequency (passive buzzer).
Configures the active buzzer's working level (high or low).
Enables or disables prompt tones for configuration codes.
Controls the audible prompt sound when the scanner is powered on.
Configures LED and beep signals for successful reading.
Selects the keyboard layout for the scanner's input.
Allows reading barcodes that appear flipped horizontally.
Enables or disables reading of inverted (black/white) barcodes.
Retrieves current device version details.
Sets how input data casing is handled (no conversion, reverse, all caps, all lower).
Configures the automatic power-off timer based on inactivity.
Adds or modifies character strings that appear before the decoded data.
Adds or modifies character strings that appear after the decoded data.
Assigns a character to identify different barcode types.
Allows setting custom Code IDs for specific barcode symbologies.
Sets the character transmitted after scanning a code (e.g., CR, LF, Tab).
Defines how to select specific parts of the decoded data for output.
Customizes the length of the start and end segments of the decoded data.
Configures information output when the scanner fails to read a barcode.
Sets the output format for decoding results, with or without protocol.
Replaces the invisible GS character with a displayable ASCII character.
Enables or disables the scanner's ability to read URL codes.
Enables/disables reading globally and sets the default reading type for symbologies.
Controls the output of check digits for specific barcode types.
Enhances reading ability for difficult barcodes, potentially increasing speed.
Enables or disables the reading of EAN 13 barcodes.
Controls the forced output of additional codes for EAN 13 barcodes.
Enables or disables the reading of EAN 8 barcodes.
Controls the forced output of additional codes for EAN 8 barcodes.
Enables or disables the reading of UPC-A barcodes.
Controls the forced output of additional codes for UPC-A barcodes.
Allows or disallows the conversion of UPC-A barcodes to EAN 13.
Enables or disables the reading of UPC-E0 barcodes.
Controls the forced output of additional codes for UPC-E0 barcodes.
Enables or disables the reading of UPC-E1 barcodes.
Controls the forced output of additional codes for UPC-E1 barcodes.
Enables or disables the reading of Code 128 barcodes.
Sets the minimum and maximum message lengths for Code 128.
Enables or disables the reading of Code 39 barcodes.
Sets the minimum and maximum message lengths for Code 39.
Configures the output of start and end characters for Code 39.
Sets whether Code 39 supports Code 32 mode and its prefix output.
Sets whether Code 39 supports Full Asc mode.
Enables or disables the reading of Codabar barcodes.
Sets the minimum and maximum message lengths for Codabar.
Configures the output of start and end characters for Codabar.
Enables or disables the reading of Interleaved 2 of 5 barcodes.
Sets the minimum and maximum message lengths for Interleaved 2 of 5.
Enables or disables the reading of Industrial 25 barcodes.
Sets the minimum and maximum message lengths for Industrial 25.
Enables or disables the reading of Matrix 2 of 5 barcodes.
Sets the minimum and maximum message lengths for Matrix 2 of 5.
Sets the verification format for Matrix 2 of 5 barcodes.
Enables or disables the reading of Code 11 barcodes.
Sets the minimum and maximum message lengths for Code 11.
Sets the verification mode for Code 11 barcodes.
Enables or disables the reading of MSI barcodes.
Sets the minimum and maximum message lengths for MSI.
Enables or disables the reading of RSS-14 barcodes.
Enables or disables the reading of Limited RSS barcodes.
Enables or disables the reading of Extended RSS barcodes.
Sets the minimum and maximum message lengths for Extended RSS.
Enables or disables the reading of QR Codes.
Enables or disables the reading of Data Matrix Codes.
Enables or disables the reading of PDF417 barcodes.
Saves the current configuration settings.
Reverts settings or cancels previous operations.
Allows setting multiple parameters simultaneously by reading a QR code.