48
9. Batch Processing Settings
When multiple settings are required to read the device, setting one by one may be
cumbersome. The user can save all the information that needs to be set as a QR code, and
the device can complete multiple settings after reading the QR code.
The following are the guidelines for batch processing:
(1) Batch processing setting code content format:
@WSM+ [Command parameter 1],
[Command parameter 2],
[Command parameter n]
For the command parameters that can be set in batches, please refer to Appendix G Batch
Setting Command Parameter List.
(2) Every two parameters are separated by an English semicolon ";", and the end is ended
by an English semicolon. Note that there can be no spaces between the semicolon and
the command.
(3) The batch setting allows up to 30 parameter settings at the same time.
(4) Make the setting content that conforms to the batch processing setting code format as
a QR code in the coding software and read the setting code for batch setting.
For example: turn on the setting code (command parameter: 00000000), induction mode
(command parameter: 02000003), the fill light is on when taking pictures (command
parameter: 03000000), single reading time -3000ms (command parameter: 0202001E),
prohibition Read the command code of Interleaved 2 of 5 (command parameter:
070A0100), then the batch setting code content is as follows:
@WSM00000000; 02000003; 03000000; 0202001E; 070A0100;
When batch setting is required, the setting can be completed by reading the batch setting
code that has been produced.
Note:
• When performing batch settings, you must ensure that "setup code is turned on".
• If the content of the batch setting code does not meet the setting code rules, or the
setting command parameters are not included in the list of settable parameters, the
setting failure will occur.