11
Read the following setting codes to set the same code reading delay time. Setting range:0ms~
12700ms
Note: You need to turn on "Same code reading delay" before you can set the delay time.
500ms
1000 ms
3000 ms
3. Single reading time
Please refer to section 3.1.2 for the setting of single reading time duration setting.
3.4 Induction mode
The induction mode refers to a working mode in which the reading module enters the reading by
sensing the changes in the brightness of the surrounding environment. When the scene changes, the
reading module starts to read. After the reading is successful and the output information or the single
reading time expires, the reading module needs a certain interval (settable) to re-enter the
monitoring state. If the following conditions do not occur, the reading module will work in cycles as
described above: if the barcode is not scanned within a single reading time, the reading module will
automatically suspend the reading and enter the monitoring state. In the induction reading mode,
the reading module can also start to read the code after pressing the trigger button and continue to
monitor the brightness of the surrounding environment when the code is successfully output or the
trigger button is released.
Induction mode
1. Single reading time
Please refer to section 3.1.2 for the setting of single reading time duration setting.
2. Reading interval time
Please refer to the setting code of reading interval time in section 3.3.1 to set the reading interval
time.