Dimension One Spas – Reflections Owner’s Manual
34
Electrical System
Symptom Problem Corrective Action
Will not turn on –
in any mode
No power Check circuit breaker and/or GFCI
Turns on by itself Normal automatic
daily filtration, or anti-
freeze cycle
No action required
Light is out
Burned out bulb Replace bulb
1. Automatic timer
has shut pump
off
1. Push JETS Button again to start another cycle. If desired, reprogram
automatic pump timer for longer duration.
Pump shuts
down
unexpectedly
while in use
2. Motor over-
heated and
automatic
protective
device has shut
down pump(s)
2. If pump(s) will not restart when JETS Button is pushed, call for service
Make sure that the equipment panel vent area is not blocked. Vent
blockage can cause serious damage to your equipment.
1. Check water level, adjust if needed
2. Clean filter
If problem persists:
1. Turn power off at GFCI breaker, then back on
3 flashing lights
on the Topside
Control
Possible sensor errors
If problem still persists: Call your dealer for Service
Water System
Symptom Problem Corrective Action
Pulsing jets
Water level too low Fill spa to proper water level
1. Jets turned off 1. Turn jets on by turning jet face clockwise
2. Selector Valve
turned
2. Turn the Selector Valve to the appropriate position
3. Dirty Filter 3. Clean Filter
4. Air lock 4. Loosen pump union to allow air to bleed
No Jet Action,
or action is
poor
5. Gate valve
closed
5. Open gate valve
1. Check water level
2. Clean filter
3. If problem continues:
Turn power off at GFCI breaker, then back on
“Check Water
Level”
message or 3
flashing lights
on control
panel
Possible sensor errors
If problem still persists, call your dealer for service