OPTIFLAME ELECTRIC FIREPLACE
TROUBLE SHOOTING GUIDE
APPEARANCE
Problem Flame frozen.
Probable Cause Loose wiring or defective flame motor.
Solution Check all wiring for loose connections, repair/replace
as necessary. If wiring connections are suitable,
replace flame motor.
Service Manual Reference Page 11
Problem Flame not bright, flame not visible.
Probable Cause Loose wiring or burnt out light bulb(s).
Solution Check all wiring for loose connections, repair/replace
as necessary. Check light bulb(s), replace burnt out
bulbs with factory specified bulbs.
Service Manual Reference Page 9
Problem Flame shudder.
Probable Cause Defective flame motor.
Solution Replace flame motor with a new one.
Service Manual Reference Page 11
Problem Log set dim, ember bed not glowing.
Probable Cause Loose wiring or burnt out light bulb(s).
Solution Check all wiring for loose connections, repair/replace
as necessary. Check light bulb(s), replace burnt out
ones with factory specified bulbs.
Service Manual Reference Page 9