Ascari MA12 -p. 33 -
Available if Paremeter # Description Setting range Ex-word settings
Electric boiler (no = O ; yes = 1) 0 or 1 1 mandatory
(1)
Maximum requested boiler's temperature
(TCMA)
21 to 80°C 75°C
(1)
Minimum requested boiler's temperature
(TCMI)
21 to TCMA °C 50°C
External command installed (switched live or
room thermostat (no = O ; yes = 1)
0 or 1 1
si = 1
Heating circuit pump linked to external
command (no = O ; yes = 1)
0 or 1 1
si = 1
Autoadaptability or automatic adjustment of the
requested temperature (no = O ; yes = 1)
0 or 1
(2)
1
Outside sensor (no = O ; yes = 1) 0 or 1 0 mantatory
si = 1
(1)
Maximum outside temperature (TEMA) n/a 11 to 25°C 20°C
si = 1
(1)
Minimum outside temperature (TEMI) n/a -30 to +10°C -5°C
si = 1
utomatic tipping up summer mode
(no = O ; yes = 1)
n/a 0 or 1 0
Operating postponement
1 to 6 min
(3)
2 min.
Indirect Hot Water production
(no = O ; yes = 1)
0 or 1 0
si = 1 DHW sensor (no = O ; yes = 1) 0 or 1 0 mantatory
si = 1
Legionnaires disease free mode (off)
(no = O ; yes = 1)
n/a 0 or 1 0
si = 1
Engaging of 6 power stages
(no = O ; yes = 1)
0 or 1 0
si = 0
Engaging stage 1
(no = O ; yes = 1)
0 or 1 1
si = 0
Engaging stage 2
(no = O ; yes = 1)
0 or 1 1
si = 0
Engaging stage 3
(no = O ; yes = 1)
0 or 1 0
si = 0
Engaging stage 4
(no = O ; yes = 1)
0 or 1 1
si = 0
Engaging stage 5
(no = O ; yes = 1)
0 or 1 0
si = 0
Engaging stage 6
(no = O ; yes = 1)
0 or 1 1
PARAMETERS LISTING
Press and during 3 sec to access parameters menu.
(1)
: See § 7 to set the heating diagram according to 4 paremeters (TCMA, TCMI, TEMA and TEMI)
(2)
: Prohibited when using a scheduled external command
(3)
: Depending on water flow rate and volume inside the heating circuit, the boiler might start at very short
intervals with wear and tear resulting. To reduce the number of cycles, increase postponement.
NOTE : To reset autoadaptability, zero parameter # , then set value to 1.