PARTS & SERVICE MANUAL
FOR THE 30” FIREPLACE
MODEL NUMBER:
EF3003
SF3003
DF3003

Other manuals for Dimplex EF3003

Questions and Answers

  • J
    jonathan01Sep 12, 2025
    What to do if Dimplex Indoor Fireplace does not turn on?
    • R
      Ryan BushSep 12, 2025
      If your Dimplex Indoor Fireplace isn't turning on, there could be several reasons: * Improper operation. Please, refer to User’s Guide. * Defective main on/off switch. You should replace the main on/off switch. * Defective remote control. Try installing new batteries into the handheld transmitter or reinitialize it. * Loose wiring. Check the wiring connections.
  • C
    cardenasrichardSep 12, 2025
    Why does my Dimplex Indoor Fireplace trip the circuit breaker?
    • C
      Crystal DunnSep 12, 2025
      The circuit breaker may be tripping because the current rating of the circuit is being exceeded by the fireplace and other appliances. Try plugging the Dimplex Indoor Fireplace into another outlet or installing it on a dedicated 15 amp circuit.
  • M
    Michael BowmanSep 10, 2025
    Why is light leaking around the log set of my Dimplex EF3003 Indoor Fireplace?
    • S
      Sierra AguilarSep 10, 2025
      If light is leaking around the log set of your Dimplex Indoor Fireplace, the log set may not be positioned properly. Check the log set for proper fit.
  • W
    williamsamySep 9, 2025
    How to fix flame shutter on Dimplex Indoor Fireplace?
    • K
      Kathleen MercerSep 9, 2025
      If you have a flame shutter issue with your Dimplex Indoor Fireplace, it could be a defective flicker motor, and you should replace it.
  • B
    bradyrobertSep 8, 2025
    Why is my Dimplex Indoor Fireplace control panel buzzing?
    • M
      Michael ElliottSep 8, 2025
      If you hear a buzzing noise from the control panel of your Dimplex Indoor Fireplace, the Flame Speed Controller may be defective. Replace the Flame Speed Controller.
  • G
    Gloria SmithAug 23, 2025
    Why does my Dimplex Indoor Fireplace keep tripping the circuit breaker?
    • J
      Joe HartAug 23, 2025
      If the circuit breaker trips or a fuse blows when you turn on your Dimplex Indoor Fireplace, it could be due to a short in the unit's wiring, in which case you should trace the wiring. Alternatively, additional appliances might be exceeding the current rating of the circuit breaker or fuse. Try plugging the unit into another outlet or installing it on a dedicated 15 amp circuit.
  • J
    Jeremy AdkinsSep 6, 2025
    Why is my Dimplex EF3003 Indoor Fireplace making grinding noises with the heater off?
    • J
      Justin ArroyoSep 6, 2025
      If your Dimplex Indoor Fireplace makes grinding or excessive noise when the heater is off, the flicker rod might be hitting or rubbing against internal components. Ensure the rod is straight and mounted properly in the bracket, spinning freely away from other components. Replace if necessary. A defective Flicker Motor could also be the cause, requiring replacement.
  • Y
    yvette34Sep 5, 2025
    How to troubleshoot a frozen flame on my Dimplex Indoor Fireplace?
    • M
      Maria RiddleSep 5, 2025
      If the flame is frozen on your Dimplex Indoor Fireplace, it could be a defective Flicker Motor, which would need replacement. Alternatively, the Flame Speed Control may be defective, so replace the Flame Speed Control Components. Loose wiring can also cause this issue, so check the wiring connections.
  • C
    Christina VaughnSep 4, 2025
    Is it normal for the heating element in my Dimplex EF3003 to glow red?
    • D
      Deborah NolanSep 4, 2025
      Small glowing sections of the heating element in your Dimplex Indoor Fireplace are considered normal. However, if larger glowing sections are causing the heater to trip the thermal cutout, unplug the unit, discontinue use, and replace the heater assembly.
  • J
    Judith MontoyaSep 3, 2025
    Is it normal for the Dimplex EF3003 power cord to get warm?
    • F
      Frances WestSep 3, 2025
      The power cord of your Dimplex Indoor Fireplace may get slightly warm during normal operation when the heater is on. However, if the cord gets hot to the touch, replace the power cord, as it may be defective.

Summary

Fireplace Operation and Remote Control

Initialize Remote Control

Steps to set up and pair the remote transmitter with the fireplace.

Remote Control Operation

Operating the fireplace features using the remote control.

Manual Fireplace Controls and Safety Features

Manual On;Off Switch

Using the physical power switch located on the fireplace unit.

Temperature Cutoff Switch Reset

Procedure to reset the heater's safety overheat protection.

Fireplace Wiring Diagram

Lower Bulb Replacement

Upper Bulb Replacement

Flame Motor;Flame Rod Replacement

Heater Assembly Replacement

Dimplex EF3003 Specifications

General IconGeneral
TypeElectric Fireplace
Weight40 lbs
Remote ControlYes
Fuel TypeElectric
Voltage120 V
Flame EffectLED Flame Effect
Wattage1, 500 Watts
BTU5100 BTU
Heating Area400 sq ft