OPERATOR’S MANUAL with Maintenance Information
Maintenance
64
82 Left Rear Otrg Coil Flt
Power FET, channel LEFT
REAR OUTRIGGER fails
check the wiring,
replace the valve
83 Right Front Otrg Coil Flt
Power FET, channel RIGHT
FRONT OUTRIGGER fails
check the wiring,
replace the valve
84 Right Rear Otrg Coil Flt
Power FET, channel RIGHT
REAR OUTRIGGER fails
check the wiring,
replace the valve
85 Outrigger Ext Coil Fit
Power FET, channel EXTEND
OUTRIGGER fails
check the wiring,
replace the valve
86 Outrigger Ret Coil Fit
Power FET, channel RETRACT
OUTRIGGER fails
check the wiring,
replace the valve
Wrong Machine Type Selected
Remove the excess
load immediately.
Machine Tilted Beyond Safe
Limits Fault
check the wiring,
replace the sensor
For more information, please consult the appropriate Dingli Service Dept.