OPERATORS MANUAL with Maintenance Information
Maintenance
64
Display
for
Platform
Display for Ground
Description
Repair
82
82 Left Rear Otrg Coil Flt
Power FET, channel LEFT
REAR OUTRIGGER fails
check the wiring,
replace the valve
83
83 Right Front Otrg Coil Flt
Power FET, channel RIGHT
FRONT OUTRIGGER fails
check the wiring,
replace the valve
84
84 Right Rear Otrg Coil Flt
Power FET, channel RIGHT
REAR OUTRIGGER fails
check the wiring,
replace the valve
85
85 Outrigger Ext Coil Fit
Power FET, channel EXTEND
OUTRIGGER fails
check the wiring,
replace the valve
86
86 Outrigger Ret Coil Fit
Power FET, channel RETRACT
OUTRIGGER fails
check the wiring,
replace the valve
95
95 Machine Type Fauit
Wrong Machine Type Selected
Reinstall Machine
Type
OL
98 Platform Overload
Platform Overload Fault
Remove the excess
load immediately.
LL
Machine Tilted Beyond Safe
Limits Fault
check the wiring,
replace the sensor