EasyManua.ls Logo

Dingtek DF702 - Reference Instruction for LoRa Parameters; Set DEVADDR Parameter; Set DEVEUI Parameter; Set NWKSKEY Parameter

Dingtek DF702
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page
14
Figure5.9
Reference instruction:
Set DEVADDR
AT+ID=DevAddr,
4 bytes length hex identifier
eg: AT+ID=DevAddr, "01234567"
Set DEVEUI
AT+ID= DevEui, 8 bytes length hex identifier (64bits)
eg: AT+ID=DevEui, "0123456789ABCDEF"
Set NWKSKEY
AT+KEY=NWKSKEY, 16 bytes length key
eg: AT+KEY=NWKSKEY,"2B7E151628AED2A6ABF7158809CF4F3C"
Set APPSKEY
AT+KEY=APPSKEY, 16 bytes length key
eg:
AT+KEY=APPSKEY,"2B7E151628AED2A6ABF7158809CF4F3C"
Detailed instructions, please refer to the [RHF-PS01509] LoRawan Class AC AT Command
Specification - v4.3.pdf document
Note: If you are facing following problems you can overcome easy way.