Figure5.9
Reference instruction:
Set DEVADDR:
AT+ID=DevAddr,
“
4 bytes length hex identifier
”
eg: AT+ID=DevAddr, "01234567"
Set DEVEUI:
AT+ID= DevEui, “8 bytes length hex identifier (64bits)”
eg: AT+ID=DevEui, "0123456789ABCDEF"
Set NWKSKEY:
AT+KEY=NWKSKEY, “16 bytes length key”
eg: AT+KEY=NWKSKEY,"2B7E151628AED2A6ABF7158809CF4F3C"
Set APPSKEY
AT+KEY=APPSKEY, “16 bytes length key”
eg:
AT+KEY=APPSKEY,"2B7E151628AED2A6ABF7158809CF4F3C"
Detailed instructions, please refer to the [RHF-PS01509] LoRawan Class AC AT Command
Specification - v4.3.pdf document
Note: If you are facing following problems you can overcome easy way.