EasyManuals Logo

Directed Electronics PYTHON 872 User Manual

Directed Electronics PYTHON 872
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
© 2009 Directed Electronics. All rights reserved.
4. Siren Duration
30sec: the siren output for full trigger activations and Panic mode is 30 seconds1.
60sec: the siren output for full trigger activations and Panic mode is 60 seconds2.
5. Ign-controlled Locks
No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned on/off1.
Lock & Unlock: the door lock & unlock output will activate when ignition is turned on & off2.
Lock Only: the door lock output will activate when ignition is turned on3.
Unlock Only: the door unlock output will activate when ignition is turned off4.
6. Door Lock Pulses
Single: the door lock & unlock outputs will pulse once 1.
Double Unlock only: the unlock output only will pulse twice 2.
Double Lock Only: the lock output only will pulse twice 3.
Double Lock & Unlock: the lock & unlock outputs will pulse twice4.
7. Door Lock Output Duration
0.8sec.: the door lock output pulses will be 800mS in duration1.
3.5sec.: the door lock pulses will be 3.5 seconds in duration2.
0.4 sec.: the door lock pulses will be 400mS in duration3.
8. Ignition Controlled 2nd Unlock
After first unlock: for Ign-controlled unlocking, the 2nd unlock will activate 800mS after the first (driver 1.
door) unlock
With first unlock: for Ign-controlled unlocking, the 2nd unlock will activate at the same time as the first 2.
(driver door) unlock
9. Comfort Closure
No comfort Closure: Comfort Closure is defeated when arming 1.
Comfort Closure 1: the door lock pulse (or 2nd pulse for double pulses) will remain on for 20 sec-2.
onds.
Comfort Closure 2: 800mS following the end of the door lock pulse (or 2nd pulse for double pulses); 3.
the door lock output will turn on again for 20 seconds.
10. Horn Function
Full Alarm Only: the horn output will pulse only during full trigger events.1.
Siren Function 20/30/40/50ms: The horn output will emulate the siren output with selectable chirp 2.
output timing to compensate for OEM horn inefficiency.
11. Hood Switch Type
Normally Open: for vehicles with a hood switch that rests at ground when the hood is OPEN1.
Normally Closed: for vehicles with a hood switch that rests at ground when the hood is CLOSED2.
12. Sensor Full Trigger
Single: full trigger activation of only one sensor is required to fully trigger the alarm1.
Double: full trigger activation of two sensors within a ten second period is required to fully trigger 2.
the alarm.
13. Door Switch Type
Normally Open: for vehicles with door switches that rest at ground when the door is OPEN1.
Normally Closed: for vehicles with door switches that rest at ground when the door is CLOSED2.
14. Trunk Switch Type
Normally Open: for vehicles with a trunk switch that rests at ground when the trunk is OPEN1.
Normally Closed: for vehicles with a trunk switch that rests at ground when the trunk is CLOSED2.
15. Remote Button Unlock (Ign off)
On: a message telling the remote control to unlock the keypad is sent each time the vehicle ignition 1.
is turned off
Off: no message is sent2.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Directed Electronics PYTHON 872 and is the answer not in the manual?

Directed Electronics PYTHON 872 Specifications

General IconGeneral
BrandDirected Electronics
ModelPYTHON 872
CategoryCar Alarm
LanguageEnglish

Related product manuals