6. Turbo Mode
No turbo Mode: Turbo mode is not available1.
On – 1/3/5/10 minutes: Turbo Mode is available and, when activated, the engine will run for the 2.
duration set per the selected option
7. Timer Mode Runtime
12/3/6/9 minutes: sets the runtime when the engine is started by the Timer Mode and SmartStart ฀
features
8. Flex Relay Function
Ignition 2: the relay will emulate the Ignition 1 output during remote start1.
Accessory 2: the relay will emulate the Accessory 1 output during remote start2.
Starter 2: the relay will emulate the Starter output during remote start3.
9. Diesel Start Delay
Wait-to-start input: (-) input on the Grey/black (H2/7) WTS wire will delay the starter output until the 1.
ground ceases.
Timed 15/30/45 seconds: delays the starter output per the selected option, the WTS wire does not 2.
function.
10. Accessory during Diesel Start Delay
On: the Accessory outputs (H/3 high current and H2/12 low current) will be ON during diesel start 1.
delay
Off: the Accessory outputs (H/3 high current and H2/12 low current) will be OFF during diesel start 2.
delay
11. Status 2 Output (Dark Blue H2/10 wire)
Status: the output will activate before the ignition outputs turn on, and de-activate after they turn off 1.
during remote start
Latch rear defogger: the output activates 10 seconds after start if the interior temperature is below 2.
55F. It turns off after 10 minutes or upon remote start off
Pulse rear defogger: the output activates (for 800mS) 10 seconds after start if the interior temperature 3.
is below 55F.
12. Parking Light Output
Constant: the lights will turn on solid during remote start1.
Pulsed: the lights will pulse on/off during remote start2.
Off: the lights will be off during remote start3.
13. Anti-grind Output
On: the high current starter relay will be activated during remote start as anti-grind protection.1.
Off: the high current starter relay will not be activated during remote start, no anti-grind protection 2.
is available.
14. Tach Mode Starter Release
Normal: the starter output will release normally during cranking (50% of the learned tachometer 1.
value)
Increase: the starter output will release later during cranking (at 35% of the learned tachometer 2.
value)
Decrease: the starter output will release sooner during cranking (at 35% of the learned tachometer 3.
value)
15. Vehicle Temp Auto Report
Off: the report during remote start is defeated1.
On: the report is sent every 2 minutes during remote start if the temperature has changed (+/-) 1 2.
degree since the last report
16. Remote start Safelock
Off: the Door lock and Factory Alarm Re-arm outputs will maintain the current status (locked/un-1.