Symptom Cause
Solution
A
The unit does not come on.
• Power cable fuse blown.
Electronic control power fuse blown.
Power cable disconnected, cut or
inverted.
Control panel internal switch position
incorrect (operation with engine switched
off, switch in trucks only).
• Power cable inverted.
• Power cable not connected.
Replace the power cable 50A fuse, checking and correcting the cause of the failure.
Replace the 15A (24V) or 25A (12V) fuse of the electronic control power cable (accessed by
taking down the control panel).
Check connections or possible breakage, correcting or replacing.
Check the position of the switch. Place in “O” trucks only (operation with engine switched off)
(Accessed by taking down the control panel).
Check and repair the connections.
Check and repair the connections.
B
The unit gives out a beeping sound.
Control panel and electronic control
connection cable poorly connected or
inverted.
Take down the control panel and connect the wiring between the control panel and the electronic
control.
C
The display shows the symbol Lb.
• Battery running low.
Poor contact in connections (power
supply terminals or battery).
Charge or replace the battery.
Check and correct any possible poor contacts.
D
The unit does not respond to the remo-
te control.
• Remote control not programmed.
Remote control battery at; the LED does
not come on.
• Electronic control faulty.
• Remote control defective.
• Reprogramme the remote control.
Replace the remote control’s battery and reprogramme.
• Replace the electronic control (accessed by taking down the control panel).
• Replace the remote control.
E
The display shows E0 without ashing.
Poor return air sensor terminal or cable
contact.
• Return air sensor faulty.
Check the cable or terminal contacts.
• Replace the return air sensor.
F
The display shows E6 without ashing.
Poor anti-freeze sensor terminal or cable
contact.
Anti-freeze sensor faulty.
Check the cable or terminal contacts.
• Replace the anti-freeze sensor (the sensor is perforated in the evaporator).