1330 Operator’s Manual Controls - 23
Engine Controls
CMW
Engine Controls
1. Fuel shut-off valve
2. Choke
3. Rope start
4. Engine power switch
Item Description Notes
1. Fuel shut-off valve When transporting unit to or
from jobsite, or anytime
machine is parked, close
valve.
Before starting engine, open
valve.
This valve separates the fuel tank
from the engine.
2. Choke To help start cold engine,
close valve.
This valve regulates air/fuel mixture.
3. Rope start To start engine, pull rope. Engine power switch and ignition
switch must be on and fuel shut-off
valve open for this control to function.
If engine does not start after three
pulls, turn power switch off and check
for fuel blockage or electrical system
problems.
4. Engine power switch To turn power on, turn
clockwise.
To turn power off, turn
counterclockwise.
For normal operation, leave this
switch on all the time and use ignition
switch to power unit.