Service - 92 Cx Series Operator’s Manual
Procedures
Dust Ejector Valve
Check valve (shown) before startup and every 10
hours. Ensure that valve is not inverted,
damaged, plugged, or cracked.
Filter, Air
Check before startup. Change every 100 hours.
C12x
1. Remove wing nut (1) to remove air filter
cover (2).
2. Remove wing nut (3) to remove primary (4)
and secondary (5) filter elements.
3. Wipe inside of housing and wash cover.
4. Inspect elements. Replace if needed.
5. Insert secondary element and ensure it is
seated correctly.
6. Insert primary element.
7. Install wing nut.
8. Install cover and secure with wing nut.
IMPORTANT: C24x and C30x only.
t57om010w.eps