Do you have a question about the dixell XR10CX and is the answer not in the manual?
Model | XR10CX |
---|---|
Type | Temperature Controller |
Resolution | 0.1 °C |
Frontal Protection | IP65 |
Control Algorithm | ON/OFF |
Certifications | CE, RoHS |
Input Type | NTC |
Display Type | LCD |
Output Type | Relay |
Storage Temperature | -20 to +70 °C |
Accuracy | ± 0.5 °C |
Dimensions | 32 x 74 mm |
Weight | 150 g |
Important instructions to read before using the manual for easy reference and correct operation.
Essential safety measures to follow during installation, operation, and maintenance to prevent hazards.
Explanation of how the controller regulates based on probe temperature and the CH parameter for heating/cooling.
Description of cooling mode operation where the compressor activates based on setpoint and differential.
Description of heating mode operation where the output activates when temperature drops below setpoint plus differential.
Explanation of the status and meaning of each LED indicator on the controller's front panel.
Procedure to view the minimum recorded temperature using the 'down' key.
Procedure to view the maximum recorded temperature using the 'up' key.
Steps to reset the stored maximum and minimum temperature values using the SET key.
Instructions to view the current setpoint value by pressing the SET key.
Procedure to modify the setpoint value using the SET and arrow keys.
Steps to enter programming mode and modify parameter values using SET and arrow keys.
Access and navigation details for the hidden menu containing advanced parameters.
Steps to lock the front panel keypad using the UP + DOWN keys to prevent accidental changes.
Procedure to unlock the front panel keypad using the UP + SET keys.
How to turn the instrument on and off using the ON/OFF key, and its effect on regulation.
Parameters related to temperature regulation, including differential, minimum, and maximum set points.
Parameters affecting the unit of measurement, display resolution, and update delay.
Parameters for configuring temperature alarms, their recovery, and delay times.
Parameters for managing alarms related to condenser temperature, including low/high limits and recovery.
Configuration parameters for the digital input, including polarity, function, and alarm delays.
Miscellaneous parameters like serial address, probe type, and display options.
Configuration for the door switch function, including status signaling and alarm delay.
Setup for a generic external alarm, its delay, and how it affects the unit.
Configuration for a serious external alarm, its delay, and output behavior.
Setting for pressure switch function, activation count, and alarm conditions.
Function to invert the controller's action between heating and cooling modes.
How the energy saving function modifies the setpoint when the digital input is activated.
Setting the polarity for the digital input, determining activation by opening or closing contacts.
Recommendations for installing and connecting the temperature probes for accurate measurements.
Procedure to upload controller configuration parameters to a Hot Key device.
Procedure to download parameters from a Hot Key device to program the instrument.
Information on how different types of alarms (probe, temperature, external, pressure) are recovered.
List and explanation of other messages that may appear on the instrument display.
Wiring diagram and connections for the XR10CX with an 8A compressor.
Wiring diagram and connections for the XR10CX with a 20A compressor.