1601-065-M-05-07
6 installation guide
general information/specifications
operator
The 1601 operator has been designed for
high usage single lane (14 feet maximum)
vehicular traffi c control.
class:
II, III, IV
horsepower:
1/2 or 1 HP
housing:
G90 galvanized steel, painted white.
mechanical:
worm gear running in a continuous oil bath.
release method:
fail-secure mechanical
operation temperature:
10ºF to 140ºF
-12ºC to 62ºC
voltage:
115/230/460 VAC
note: 230 and 460 VAC units use a
stepdown transformer to achieve 115 VAC
operating voltage.
arm:
wood/aluminum
loop detectors:
Port for plug-in open (up) detector
Port for plug-in reverse (down) detector
DKS Detectors Only
advanced features:
Auto Close Timer 1-23
Electronic Limits
Gate Tracker
Left/Right Mount
safety Listing:
Complies with UL 325 and UL 991 safety
standards.