Model 6002
Residential Vehicular Swing Gate Actuators
DoorKing, Inc.
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Phone: 310-645-0023
Fax: 310-641-1586
www.doorking.com
Owner’s Manual
P/N 6001-065 REV E, 5/04
Copyright 2003 DoorKing, Inc. All rights reserved.

Other manuals for DKS 6002

Questions and Answers

  • W
    Wayne FoleyAug 14, 2025
    What to do if external reversing devices cannot be made operable on my DKS Controller?
    • K
      Kiara SmithAug 14, 2025
      If external reversing devices cannot be made operable, immediately remove the DKS Controller from service. Continuing to use the controller with a malfunctioning reversing system creates a hazard that can result in serious injury or death if someone becomes entrapped in the gate. Do not place this operator in service until the malfunction can be identified and corrected.
  • M
    Michael DavisAug 18, 2025
    What to do if my DKS 6002 opens but won't close?
    • J
      John BoydAug 18, 2025
      If your DKS Gate Opener opens but won't close, check the following: * Input LEDs: Any that are ON indicate a problem with a keying device. * Secondary safety devices: Any that are activated will hold the gate open, indicating a problem with the safety device. * Loop detectors: Any that are activated can hold the gate open, indicating a problem with the loop detector or ground loop. The operator may also be in a 'soft shutdown' state. Try activating any keying device to see if the operator returns to normal operation. If you want automatic closing, make sure switch 4 on SW1 is ON.
  • S
    Steven GordonAug 21, 2025
    Why does my DKS 6002 Gate Opener start to close, then reverse to open?
    • D
      David MeyerAug 21, 2025
      If your DKS Gate Opener starts to close and then reverses to open, here's what to check: * Disconnect the gate from the actuator and ensure it operates freely without any binding. * Check the loop detector LEDs and input LEDs. Any that flash ON will cause the gate to reverse. * If a shadow loop is used, verify proper wiring. A mis-wired shadow loop detector will cause the gate to reverse. If these steps don't resolve the issue, consider replacing the circuit board.
  • W
    Wanda HayesAug 27, 2025
    What to do if DKS Gate Opener opens a short distance, then stops and reverses?
    • B
      Brian YoungAug 27, 2025
      If your DKS Gate Opener opens a short distance, then stops and reverses, try the following: * Disconnect the gate from the actuator and check that the gate swings freely without any binding. * Check the reverse sensitivity. * Check the secondary safety devices. If the problem persists, replace the circuit board.
  • M
    michael87Aug 30, 2025
    Why does my DKS 6002 Gate Opener close and open continuously?
    • F
      Francisco RiggsAug 31, 2025
      If your DKS Gate Opener closes and opens continuously, check the following: * Check for any input or loop detector LEDs that are ON. * Verify that the operator is running in the proper direction (refer to the 'gate closes but will not open' information). * Check the SELF TEST jumper.
  • N
    Nicole JohnsSep 6, 2025
    How to troubleshoot a DKS 6002 Gate Opener actuator that won't run and the power LED is OFF?
    • M
      Melinda MercerSep 7, 2025
      If the actuator(s) of your DKS Gate Opener will not run and the power LED is OFF, check the following: * Ensure that power to the operator is turned ON. * Check for 24 VAC at terminals 19 and 20. If the voltage measures OK, check the terminal strip or replace the circuit board.
  • L
    Lisa MendozaSep 9, 2025
    What does it mean if my DKS 6002 alarm sounds for 5 minutes and then beeps once every 5 seconds, and the operator won't run?
    • J
      Jordan DeanSep 10, 2025
      The DKS Gate Opener is in a 'hard shutdown' condition. The reset switch must be activated to return the operator to normal operation.
  • R
    Robert MitchellNov 23, 2025
    How to fix a DKS 6002 that closes but won't open?
    • C
      Craig PachecoNov 23, 2025
      If your DKS Gate Opener closes but will not open, consider the following: * The operator may be in a 'soft shutdown'. Check the input LEDs. If any are ON, momentarily disconnect, then reconnect the wire going to the input terminal. The actuator should open. * Ensure the actuator is running in the proper direction. Turn the power OFF, disconnect the batteries, and then turn it back ON. Activate a keying device; the actuator should run in the open direction. If it runs in the close direction, turn the power OFF and change the direction switch SW1, switches 1 and/or 2. Retest and reconnect the batteries. * Confirm that the respective LED on the control board lights when the keying device connected to the respective terminal is activated. If the LED does not light, momentarily place a j...

Summary

IMPORTANT SAFETY INSTRUCTIONS

WARNING - To reduce the risk of injury or death

Crucial safety warnings to minimize the risk of injury or death during operation.

ENTRAPMENT PROTECTION

SECTION 1 - ACTUATOR INSTALLATION

1.4 Actuator Installation

Step-by-step guide for physically installing the gate actuator and its brackets.

SECTION 2 - CONTROL PANEL INSTALLATION & WIRING

2.3 Actuator Wiring

Wiring diagram for connecting master and slave actuators to the control panel.

2.4 Main Terminal Control Wiring

Wiring diagram for connecting optional control devices to the main terminal strip.

2.6 Secondary Entrapment Protection Device Wiring

Wiring instructions for connecting secondary entrapment protection devices like photo-cells.

2.8 Loop Detector and Loop Wiring

Details wiring for loop detectors to provide vehicular traffic protection.

SECTION 3 - ADJUSTMENTS

3.2 Switch Settings

Details the functions and settings for DIP switches on the control board.

SECTION 5 - MAINTENANCE AND TROUBLESHOOTING