2.7 Secondary Entrapment Device Terminal Description
1. OPEN PHOTO-BEAM
This input is only active when the gate is in the opening cycle. If the open photo-beam is
activated during the opening cycle, the gate will stop. The gate will remain stopped until
the photo-beam input is cleared, at which time the gate will resume the open cycle.
2. CLOSE PHOTO-BEAM
This input is only active when the gate is in the closing cycle. If the close photo-beam
input is activated during the closing cycle, the gate will stop. The gate will remain stopped
until the photo-beam input is cleared, at which time the gate will resume the close cycle.
Note: It is recommended that the CLOSE PHOTO-BEAM input only be used when the
input to terminals 8 and 9 are set for SHADOW operation (SW 1, switch 5 ON). If
terminals 8, 9 are set to operate as a REVERSING input (SW 1, switch 5 OFF), then
connect the CLOSE PHOTO-BEAM to these terminals as shown in figure 17.
3. NOT USED
4. NOT USED
5. COMMON
Common terminal for the secondary entrapment protection device inputs.
6. COMMON