Closing Wait Output
The XR500 Series panel now provides a Closing Wait Output in Output Options just after the Sensor
Reset Output that turns on when a closing message is successfully sent to the receiver.
CLS WAIT OUT: 0
Closing Wait Output
Enter the output number to turn on for approximately four (4) seconds when
Closing Wait is programmed as YES and the panel successfully communicates
the closing message at arming. If the closing message does not communicate
successfully, this output does not turn on. Enter zero to disable this output.
Cancel Ambush Option
The XR500 Series panel now provides a Cancel Early Morning Ambush message (C) for a zone Alarm
Action in Zone Information programming. This zone action cancels a running Early Morning Ambush
timer.
A T L -
ALARM - Select A to send an alarm report to the receiver and activate the bell
output according to zone type. The zone name appears in the panel alarmed
zones and status lists.
TROUBLE - Select T to send a trouble report to the receiver. The zone name
appears in the panel alarmed zones and status lists.
Note: UL requirements prevent the Alarm (A) and Trouble (T) action for Fire
(FI), and Fire Verify (FV) zone types from being changed.
LOCAL - When you select L, an alarm report is NOT sent to the receiver. The
bell output activates and the zone name appears in the panel alarmed zones
and status lists.
- (Dash) - When you select a (dash), reports are NOT sent to the receiver.
The bell output does not activate and there is no display in the panel alarmed
zones or status list. Only the relay output selected in the next section
operates.
D S C
CANCEL AMBUSH - Select C for the zone to cancel the Early Morning Ambush
timer and stop an Ambush message from being sent to the receiver. Faulting
the zone takes the place of a second user code being entered at the keypad
and is only available for non-fire type zones. Area assignment for the zone
does not affect this option. See Early Morning Ambush in Area Information
programming.

Other manuals for DMP Electronics 263LTE-V5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics 263LTE-V5 and is the answer not in the manual?

DMP Electronics 263LTE-V5 Specifications

General IconGeneral
BrandDMP Electronics
Model263LTE-V5
CategoryControl Panel
LanguageEnglish

Related product manuals