716 OUTPUT
EXPANSION MODULE
Specifications
Operating Voltage 12 VDC Nominal
Current Draw
Standby 13 mA
Operating 13 mA
+ 12 mA per active relay
Weight 4.8 oz. (136.0 g)
Dimensions 2.5” W x 2.5” H (6.35 cm W x 6.35 cm H)
Ordering Information
716 Output Expansion Module
Compatibility
XR150/XR550 Series Panels
Certifications
California State Fire Marshall (CSFM)
New York City (FDNY COA #6167)
Underwriters Laboratory (UL) Listed
ANSI/UL 365 Police Connected Burglar
ANSI/UL 464 Audible Signal Appliances
ANSI/UL 609 Local Burglar
ANSI/UL 864 Fire Protective Signaling
ANSI/UL 985 Household Fire Warning
ANSI/UL 1023 Household Burglar
ANSI/UL 1076 Proprietary Burglar
ULC Subject-C1023 Household Burglar
ULC/ORD-C1076 Proprietary Burglar
ULC S304 Central Station Burglar
ULC S545 Household Fire
MODEL
716
TXD
NS
2
NC
NO
C
3
NC
NO
C
4
NC
NO
C
1
NC
1
12 VDC
12 VDC
12 VDC
12 VDC
2
3
4
NO
C
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
T
E
N
S
O
N
E
S
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800.641.4282 | DMP.com
© 2020
Exceptions to Output Expansion Module Addressing
The module can only be wired to an LX‑Bus. To determine the correct output for a particular keypad zone, match the
zone number with the annunciator output number. Special addresses are configured to allow the annunciator outputs to
follow the panel and keypad zones when connected to the first LX‑Bus. Refer to Table 3.
LX‑500
ADDRESS
ZONES
LX‑500
ADDRESS
ZONES
LX‑500
ADDRESS
ZONES
LX‑500
ADDRESS
ZONES
501 1to 4 541 41to 44 519 91‑94 559 131‑134
505 5to 8 551 51to 54 529 101‑104 569 141‑144
509 9to 10 561 61to 64 539 111‑114 579 151‑154
511 11to 14 571 71to 74 549 121‑124 589 161‑164
521 21to 24 581 81to 84
531 31to 34
Table 3: XR150/XR550Series LX‑Bus Addresses and Corresponding Zones
COMPLIANCE LISTING SPECIFICATIONS
UL Listed Installations
To comply with ANSI/UL 365Police‑Connected Burglary System or ANSI/UL 609Local Burglary Alarm Systems, the
module must be mounted in the supplied, UL listed enclosure with a tamper.
Unsupervised operation is not suitable for fire listed installations.
Any auxiliary power supply for a commercial fire installation must be regulated, power limited, and listed for Fire
Protective Signaling.
ULC Commercial Burglary Installations (XR150/XR550Series Panels)
Place the output module with at least one zone expander in a listed enclosure and connect a DMP Model 307Clip‑on
Tamper Switch to the enclosure programmed as a 24‑hour zone.

Related product manuals