7000 Series Installation and Programming Guide | Digital Monitoring Products, Inc. 19
Activate Zone 3 Exit (7073/A, 7173)
Select YES to enable the Request to Exit feature on zone
3. When zone 3 shorts, the keypad relay activates. During
this time, the user can open the protected door to start
the programmed bypass entry/exit timer. If the door is not
opened within the time programmed in the Zone 3 REX
Strike Time, the relay restores the door to its locked state.
No panel programming is required.
Zone 3 REX Strike Time (7073/A, 7173)
Enter the number of REX seconds to elapse. Range is
5-250seconds. Press any select key to clear the keypad
display and enter the number of seconds. The default is 5.
ALL? NO YES (7063/A, 7073/A, 7163, 7173)
Select the number of seconds (1-9) the keypad should
wait when an area system displays ALL? NO YES during
arming/disarming or a HOME/SLEEP/AWAY system waits
during arming only. If NO or YES, or HOME, SLEEP, or
AWAY is not manually selected before the delay expires,
the keypad automatically selects YES or AWAY. Select zero
(0) to disable this feature. The delay also occurs when any
credential is presented for arming the Home/Sleep/Away
system. Default is 2.
ACTIVATE ZONE 3
EXIT: NO YES
ZONE 3 REX STRIKE
TIME: 5
ALL?: NO YES
DELAY: 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics Thinline Aqualite 7000 Series and is the answer not in the manual?

DMP Electronics Thinline Aqualite 7000 Series Specifications

General IconGeneral
BrandDMP Electronics
ModelThinline Aqualite 7000 Series
CategoryKeypad
LanguageEnglish

Related product manuals