9
4. Place the electronic control box kit (if applicable)
and the ADB kit inside the RV. These boxes con-
tain mounting hardware for the unit and will be
used inside the RV.
This completes the outside work. Minor
adjustments can be done from inside the
RV if required.
H. Installation Preparation
1. Check gasket alignment of the unit over the
roof opening and adjust if necessary. Unit may
be moved from below by slightly lifting. See
(FIG. 11).
FIG. 11
Center Unit From Below
Roof Gasket
2. Remove return air cover and ceiling template
from carton. See (FIG. 12).
FIG. 12
Divider Plate
Return Air
Cover
Ceiling
Template
Return Air
Grille
3. All models listed in this manual will use a four (4)
bolt pattern for installing the RAG kit.
4. Reach up into the return air opening and pull the
unit electric cord down for later connection. See
(FIG. 13).
d. Inspect all connections to make sure they
are tight.
e. Place cover on the thermostat and push until
an audible click is heard.
G. Placing Unit On Roof
1. Remove the unit from the carton and discard
carton.
2. LIFTING HAZARD. Use proper
lifting technique and control when lifting product.
Failure to obey this caution could result in injury.
Place unit on the roof.
3. Do NOT slide unit. Otherwise,
damage to gasket (on bottom of unit) may occur,
and could cause a leak.
Lift and place the unit over the prepared open-
ing using the gasket on the unit as a guide. See
(FIG. 9) & (FIG. 10).
FIG. 9
Do Not Slide
Lift And Place
Front
FIG. 10
Do Not Slide
Lift And Place
Front
INSTALLATION INSTRUCTIONS