CFX3 Troubleshooting
35
Alert messages
E.g. see
fig. o A, page 16.
Warning codes
E.g. see
fig. o B, page 16.
Alert message Description Possible cause Suggested remedy
!ALERT - Lid open
> 3 min
Lid open more
than 3 minutes
Lid not fully
latched
•Internal fault
Check lid latched fully
Authorised repair centre
inspection required
!ALERT - Voltage
low
The device has
stopped working
on DC due to low
voltage
Insufficient supply
voltage
Battery voltage is
too low
Battery protec-
tion is set too high
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
Test the battery and
charge as needed
Select a lower battery
protection setting
Warning code Fault Possible cause Suggested remedy
!WARNING 32 Fan over-current Internal fault. Turn off the device for at
least 5 mins., then restart. If
the problem persists,
authorised repair centre
inspection required
!WARNING 33 Compressor start
fail
!WARNING 34 Compressor
speed low
High ambient
temperature
Air vent blocked
or insufficient
clearance
•Internal fault
Turn off the device for at
least 30 mins., or move
to a cooler location,
then restart
Clear the vents
Authorised repair centre
inspection required
!WARNING 35 Controller over-
temperature