Technical data IBIS4
26
Discharge of refrigerant into the atmosphere is against the law. Severe penalties
apply.
13 Technical data
Contains fluorinated greenhouse gases. Hermetically sealed equipment.
IBIS4
IB36H401RI, IB36H401RIY
Compressor capacity: 3600 W
Cooling capacity based on ISO 5151: 2625 W
Heating capacity based on ISO 5151: 3017 W
Rated input voltage: 220 240 Vw/ 50 Hz
Rated current in cooling mode: 6.9 A
Rated current in heating mode: 6.5 A
Required fuse: 10 A
Operating temperature range: –2 °C to +52 °C
Refrigerant: R410A
Refrigerant quantity: 0.750 kg
CO
2
equivalent: 1.566 t
Global warming potential (GWP): 2088
Protection class: IPX4
Suggested max. vehicle length (with insulated
walls):
<7m
Dimensions L x W x H (height above vehicle roof): 1112 x 758 x 230 mm
Total installed weight: 40 kg
Inspection/certification: