MCS T6, MCS T12, MCS T16 Programming
17
8.6 Restore Memorized Default Settings
The memorized default settings can be restored as follows.
Enter the Program Mode.
Set P-17 to “rSt”.
Exit the Program Mode.
The software version number (e.g. “A12”) appears in the display.
The memorized default settings are restored and the Marine Climate System
returns to the Off Mode.
8.7 Programmable Parameters
Programmable Parameters Table
Program
number
Description Default Range
P-1 Operating Mode 0 0 = Automatic mode
1 = Cool only mode
2 = Heat only mode
P-2 High Fan Speed Limit
(arbitrary units)
95 65 – 95
P-3 Low Fan Speed Limit
(arbitrary units)
55 30 – 64
P-4 Compressor Staging Time
Delay
15 5 – 135 s
P-5 Temperature Sensor
Calibration
Ambient
Tem per a tur e
Ambient 10 °F, –12,2 °C
P-6 Failsafe 3 0 = Minimum protection
1 = Continuous, no display
2 = Continuous, with display
3 = Four failures, reset required
P-7 Low AC Voltage Shut-
down (Volts)
115 V – OFF
220/230 V – OFF
75 – 105
175 – 205
P-8 De-Icing Cycle 1 OFF
1 = On with 5 °F, –15 °C faceplate
sensor differential
2 = On withF,13,C faceplate
sensor differential