MSI924M Technical data
23
Overvoltage shutdown
Undervoltage shutdown
Excess temperature shutdown
Approvals
The device has E13 certification.
In compliance with the EMC directive 2004/108/EC including 2009/19/EC and
the Low-voltage Directive 2006/95/EC
EN55012: Class B
EN55014:Class B
EN61000-6-1/6-3: Class B
EN61000-6-2/6-4: Class A
EN61204-3
Overvoltage
Shutdown Restart
32 V 29 V
Undervoltage warning
Undervoltage
Shutdown Restart
21 V 21 V 25 V
Internal temperature Temperature on cooling element
Shutdown Restart Shutdown Restart
60 °C 40 °C 95 °C < 80 °C
E
MSI924M-IO-16s.book Seite 23 Mittwoch, 5. April 2017 5:18 17