Connecting the inverter MSI924M
14
8.3 Mounting the inverter
Hold the inverter against the installation location and mark the fastening points
(fig. 3 A, page 3).
Attach the inverter using your chosen fastening method (fig. 3 B, page 3).
9 Connecting the inverter
9.1 General instructions
!
When setting up a socket distribution circuit (mains setup), comply with the
applicable regulations.
Only use copper cables.
Keep the cables as short as possible (< 1.8 m).
Keep to the specified cable cross section and fit a cable fuse (fig. 6 3, page 5)
as close to the battery as possible on the positive cable (see the table).
WARNING!
The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
Reversed polarity can damage the inverter.
The inverter should not be used to connect to a ring main, it must
only be used to power individual appliances that are plugged into
the inverter outlet either directly or using a purpose-made, moulded
extension lead
Device
Required cable
cross section
Cable fuse
(fig. 6 3, page 5)
MSI924M 10 mm² 50 A
MSI924M-IO-16s.book Seite 14 Mittwoch, 5. April 2017 5:18 17